The BECSys5 is a highly sophisticated, multi-channel water chemistry controller used globally in commercial swimming pools, water parks, and industrial water treatment applications. Proper installation, precise calibration, and systematic maintenance are required to ensure safe water conditions and maximize the operational lifespan of the unit.
: The unit is housed in a NEMA 4X (IP65) enclosure, which is splash-proof but not intended for explosive environments. It must be mounted in a location with adequate ventilation.
| Category | Specification | | :--- | :--- | | | NEMA 4X (IP65 / IP66), Glass Reinforced Polycarbonate | | Dimensions | Width: 7.00 inches, Height: 10.00 inches, Depth: 4.37 inches | | Temperature Range | Ambient Operating: -18°C to 50°C (0°F to 122°F) | | Electrical (115VAC) | 115VAC 60Hz, Single Phase. 12.25 Amps Full Load (0.25A controller + 3A x 4 relays) | | Electrical (230VAC) | 230VAC 50Hz, Single Phase. 12.125 Amps Full Load (0.125A controller + 3A x 4 relays) | | Relays | 4 relays rated at 250VAC (max) – 3 Amps | | Warranty | Five years electronics, two years sensors | becsys5 installation and technical manual
The BECSys5 is housed in a NEMA 4X (IP65) enclosure. When selecting a mounting location:
If the flow cell is shipped as a kit, install the controller and assemble the flow cell components (valves, sensors, flow switch) directly to the wall. Step 2: Plumbing the Flow Cell The BECSys5 is a highly sophisticated, multi-channel water
Ensure the flow switch is wired to the safety interlock terminal to prevent chemical dosing without water flow. 3. Technical Features and Functionality offers a sophisticated feature set for pool management: System Inputs: Monitors pH, ORP, Temperature, and Flow.
This technical manual serves as an exhaustive reference guide for commercial pool operators, field technicians, and facility engineers responsible for the deployment and upkeep of the BECSys5 controller. 1. Product Overview and Technical Specifications It must be mounted in a location with adequate ventilation
: Do not power on the server until all field controllers are wired to prevent stray BACnet traffic from flooding error logs.
Alternatively, configure manually via each controller’s web page (http:// , default creds: becsys5 / field01 ).
Carefully unpack the proprietary sensors. Inspect the glass bulbs (pH) and platinum bands (ORP) for fracture fractures. Thread the sensors slowly into the flow cell housing by hand until seated against the integrated gaskets. Do not overtighten, as this can crack the sensor bodies. 2. True PPM Amperometric Chlorine Sensor BECSys5 Installation and Technical Manual - Googleapis.com
Network wiring