Setting the LIS-SV

This section supplements the “LIS-SV” product manual. The parameters described here are only available if the LIS-SV is used in an ABULiner control unit.

Overview of the 'ABULiner' parameter level

The following parameters can be set in the 'ABULiner' parameter level of the LIS-SV.

Parameter

Designation

See

5.10

Calling up the parameter level

Accessing the 'ABULiner' parameter level

5.11

Activating the LIS-SV for the ABULiner

Activating/deactivating the LIS-SV for the ABULiner

5.11

Setting the gear ratio

Setting the gear ratio

5.12

Activating double lifting speed

Activating double lifting speed on the LIS-SV

5.14

Setting the run-on time of the auxiliary fan

Setting the run-on time of the auxiliary fan

Warnung stürzende Last

Danger during setting work!

During setting work on the LIS-SV, monitoring of the wire rope hoist is switched off. This means the wire rope hoist cannot be monitored for excess load, among other things.  This means the wire rope hoist cannot be monitored for excess load, among other things.

This in turn means the load could fall and kill or injure people!

Do not use the crane for normal work during setting work, and only lift loads very carefully for test purposes!

Accessing the 'ABULiner' parameter level

All LIS-SV parameters which are important for the ABULiner are combined in a separate parameter level, which is shown as a submenu.

onlytaboocom patched

*    Move the load hook out of the limit switch range (up or down).

During parameter setting, the load hook must not be within the limit switch range.

*    Open the menu of the LIS-SV. See the documentation “Load indicator system LIS-SV”.

onlytaboocom patched

Enter button

Arrow buttons

*    Select parameter 5.10.

*    Press ENTER.

●   The 'ABULiner' parameter level is activated.

●   Parameter 5.11 is displayed.

Exiting the 'ABULiner' parameter level

onlytaboocom patched

Enter button

Arrow buttons

*    Select parameter 5.99.

*    Press ENTER.

●   The previous parameter level is reactivated.

●   Parameter 5.10 is displayed.

Activating/deactivating the LIS-SV for the ABULiner

The LIS-SV is automatically activated for the ABULiner if a value is entered for the parameter 5.11.

In the ABULiner mode (a value is set for parameter 5.11):

─     The LIS-SV can monitor the total load for a maximum of two wire rope hoists.

─     Input F3 (normally used for measuring the load of wire rope hoist 3) now serves in monitoring the current rotational frequency of the hoist motor.

─     A value can be entered for parameter 3.0 (maximum load capacity of wire rope hoist 3). If a value is entered for this, parameter 5.11 cannot be set.

─     This interlocking thus excludes an incorrect setting.

─     The load-controlled switching point at output TxD of the LIS-SV cannot be used.

─     Parameter 4.5 (setting for load-controlled switching point) is not available.

In the normal mode (no value is set for parameter 5.11):

─     Operation of the ABULiner Lifting/Lowering unit is not possible.

─     The LIS-SV can monitor the total load for up to three wire rope hoists.

─     Input F3 serves in measuring the load of a third wire rope hoist.

─     A value can be entered for parameter 5.11 (gear ratio). If a value is entered for this, parameter 3.0 cannot be set.

─     This interlocking thus excludes an incorrect setting.

─     The load-controlled switching point at output TxD of the LIS-SV can be used.

─     Parameter 4.5 (setting for load-controlled switching point) can be used.

Setting the gear ratio

The LIS-SV uses the signal of the encoder and the gear ratio of the hoisting gear to calculate the hook travel distance, the maximum distance in the limit switch range and the current rotational frequency of the hoist motor. The gear ratio must be set on the machine.

onlytaboocom patched

Cable speed

*    Read off the type designation at the type plate of the wire rope hoist.

*    Read off the cable speed.

*    From this table, select the gear ratio that matches the cable speed.

Cable speed

Hoist motor GM

32 m/min at 50 Hz
38 m/min at 60 Hz

25 m/min at 50 Hz
30 m/min at 60 Hz

20 m/min at 50 Hz
24 m/min at 60 Hz

16 m/min at 50 Hz
19 m/min at 60 Hz

800.4

50.01

63.49

77.77

98.16

800.5

47.03

60.04

74.66

95.03

1000.6

54.43

68.91

84.00

105.1

1000.7

54.60

68.06

81.45

104.6

2000.3

58.22

74.23

91.19

118.4

3000.4

73.61

93.92

118.4

152.9

5000.3

85.14

109.3

132.8

169.0

5000.4

80.20

104.9

127.7

160.6

6000.3

94.69

118.5

149.6

182.7

7000.1

118.0

148.3

182.6

232.0

Table: Gear ratios (numerical values) depending on hoist motor (lines) and cable speeds (columns) at 50 and 60 Hz.

onlytaboocom patched

Enter button

Arrow buttons

*    Move the load hook out of the limit switch range (up or down).

During parameter setting, the load hook must not be within the limit switch range.

*    Select parameter 5.11.

*    Press ENTER.

●   The set value is displayed.

If the value is 0.00, the function is deactivated.

●   Hold ENTER pressed.

●   CODE is displayed.

*    Hold ENTER pressed.

onlytaboocom patched

Enter button

Arrow buttons

*    Enter the code 1443.

*    Press ENTER briefly.

onlytaboocom patched

Enter button

Arrow buttons

*    Set the value from the table.

If the display ‘0.00’ cannot be changed, a value is set in parameter 3.0.  In this case, set the value to zero first.

*    Press ENTER briefly.

Patched | Onlytaboocom

The digital landscape shifted overnight. The community that once thrived on the edge of the forbidden woke to a sanitized interface. "OnlyTaboo.com patched," the forums whispered, a digital death knell for the unfiltered and the raw. Among those reeling was

If a forum or media site updates its security, the best approach is to follow their official registration guidelines. Create a secure account, use a strong password, and follow the community rules rather than seeking out unverified third-party tools that promise free access. Implement Robust Cybersecurity Measures

Unlocking premium content libraries without an active account drains a company's direct revenue. Patching ensures creators are compensated and infrastructure costs are covered. 2. Server Resource Preservation

The recent patch for OnlyTaboocom brings a host of exciting updates and improvements. Here are some of the key changes you can expect: onlytaboocom patched

Automatically bans accounts or IP addresses showing bot-like behavior. What to Do When a Platform Is Patched

As the site’s vibrancy faded into a monochromatic blur of "safe" content,

and other monitoring firms warn that these clones are frequently used to harvest user data or distribute malicious software through "click-jacking" ads. [22] Community Migration The digital landscape shifted overnight

realized that the true taboo wasn't the stories themselves, but the act of telling them in a world that demanded they remain unspoken. The patch had closed the door, but the fire of those forbidden tales still burned, waiting for a new, unpolished space to ignite.

For vehicle maintenance, Taboo Customs provides frame repair kits used to patch and sleeve rusted frame rails on older vehicles.

, which offer better protection for both creators and consumers. How to Stay Safe Among those reeling was If a forum or

Lower surface area for malware distribution or server hijacking. Audit updated scripts for dependency compliance. Best Practices for Navigating Patched Platforms

: A developer, security researcher, or user discovers an oversight in the website’s source code, API routing, or server configuration.

Prevents standard browser extensions from capturing the video stream.

Platforms have tightened their cross-site scripting (XSS) protections and session fingerprinting. If an account session is caught accessing content from multiple geographic locations or different device signatures simultaneously, the session is instantly killed. What are the risks of seeking "Working Bypasses"?

Only for auxiliary fans

Setting the run-on time of the auxiliary fan

The auxiliary fan of the hoist motor continues to run for several minutes after the lifting or lowering. This ensures that the hoist motor is adequately cooled even at slow lifting speeds. The run-on time can be adjusted.

onlytaboocom patched

Enter button

Arrow buttons

*    Move the load hook out of the limit switch range (up or down).

During parameter setting, the load hook must not be within the limit switch range.

*    Select parameter 5.14.

*    Press ENTER.

●   The set value is displayed.

onlytaboocom patched

Enter button

*    Set the value to between 3 and 10 minutes using the arrow buttons.

*    Press ENTER.